Home  /  Glossary  /  What is commercial solar PV?Last updated

Business Energy Glossary

What is commercial solar PV?

Commercial solar PV is photovoltaic generation installed on commercial premises (rooftops or ground-mounted) to provide electricity for on-site consumption with surplus exported to the grid. Typical UK commercial systems range from 50 kWp (a small warehouse) to 1 MWp (a large industrial roof or solar field). Larger commercial installations above 1 MWp typically operate as utility-scale or PPA-backed projects rather than self-consumption.

Lower equipment costs and higher electricity prices have made commercial solar worth assessing for many businesses with daytime demand. Payback depends mainly on how much generation is used on site, and is often longer where export is high. Understanding the commercial PV proposition matters when evaluating capital allocation for any building with available roof or land.

How commercial solar PV works

Commercial solar PV means photovoltaic panels fitted on a business building or its land to produce electricity for the site. Power is used on site first, with any surplus exported to the grid, where it can earn a Smart Export Guarantee payment. Systems usually range from tens of kilowatts to several megawatts.

A commercial PV system has three main components:

  • PV modules. Solar panels installed on a rooftop or ground-mounted array, converting sunlight to DC electricity.
  • Inverters. Convert DC from the panels to AC compatible with the building electrical system and grid.
  • Connection equipment. Isolators, metering, and grid protection equipment.

The PV output is consumed on-site first. Any surplus flows out through the site connection to the grid. The site continues to import from the grid when PV output is below consumption (overnight, cloudy periods, peak loads).

Sizing for commercial sites

Typical UK commercial PV installations by site type:

Site typeTypical PV sizeAnnual output
Small office or shop20-50 kWp17-43 MWh
Warehouse / industrial unit100-500 kWp85-425 MWh
Large distribution centre500 kWp – 2 MWp425-1,700 MWh
Solar farm (ground-mounted)2-50 MWp1,700 MWh – 42 GWh

UK PV output is approximately 850 kWh per kWp per year for well-oriented south-facing arrays. Lower for east-west arrays (around 750 kWh/kWp).

Self-consumption vs export

The financial value of PV output depends heavily on the proportion self-consumed:

  • Self-consumed kWh. Valued at the full grid import price (typically 20 to 30 p/kWh for UK business).
  • Exported kWh. Valued at the Smart Export Guarantee rate (typically 3 to 8 p/kWh) or PPA price for larger installations.

For typical commercial sites operating during daylight hours (offices, warehouses, retail), self-consumption proportions of 60 to 80 per cent are common for well-sized systems. Sites operating only outside daylight hours (night warehouses, late-evening venues) have lower self-consumption.

Commercial PV economics

Typical 2024 UK commercial PV economics:

  • Capital cost. £600 to £900 per kWp installed (lower for larger systems).
  • Annual generation. 750 to 900 kWh per kWp.
  • Value per generated kWh. Blended 15 to 25 p/kWh (mix of self-consumption and export).
  • Annual revenue per kWp. £110 to £225.
  • Simple payback. 5 to 8 years.
  • IRR. 10 to 18 per cent over 25-year lifetime.

Economics depend on roof orientation, shading, consumption pattern, and grid connection capacity. A bespoke feasibility study is essential before commitment.

Solar PV with battery storage

Adding battery storage to commercial PV:

  • Stores surplus daytime PV for use in early evening peak periods.
  • Increases self-consumption proportion from 60-80 per cent to 80-95 per cent.
  • Can also provide grid services (frequency response, capacity market) for additional revenue.
  • Capital cost adds £300 to £600 per kWh of storage capacity.
  • Improves PV economics when grid import vs export price spread is wide.

Storage typically makes sense for sites with significant evening consumption (manufacturing with shift work, hotels, leisure centres) or for sites pursuing additional grid services revenue.

Practical considerations

Key practical issues:

  • Roof structural assessment. Required for rooftop installations to confirm the roof can support the added load.
  • Grid connection capacity. The site connection must accommodate export above consumption; Systems above 16A per phase need network operator approval under G99 before connection.
  • Planning permission. Required for ground-mounted systems above 50 kWp; permitted development typically applies to rooftop.
  • Lease and tenant arrangements. Where the building is leased, who owns the PV and who benefits from generation needs clarifying.
  • O&M. Annual cleaning and inverter maintenance; inverters typically replaced once at 10-15 years.

Installations up to 50kW need MCS or equivalent certification to qualify for the Smart Export Guarantee. Larger installations follow utility-scale design and installation standards.

Where Clearsight comes in

Clearsight doesn’t install solar panels. We introduce you to vetted installer partners, gather their quotes and help you compare them on a like-for-like scope, so the differences in price are easier to understand. Once the system is running, we set up a Smart Export Guarantee tariff for the surplus and look at your electricity supply contract so it fits the way the site now uses power. We don’t arrange power purchase agreements or funded solar.

commercial solar PV FAQs

What is commercial solar PV?

Photovoltaic generation installed on commercial premises (rooftops or ground-mounted) to provide electricity for on-site consumption with surplus exported to the grid. Typical UK commercial systems range from 50 kWp to 1 MWp.

How much electricity does commercial solar generate?

Approximately 850 kWh per kWp per year for well-oriented south-facing UK arrays. A 200 kWp system generates around 170 MWh per year, equivalent to the electricity consumption of a small to mid-size warehouse.

What is the payback on commercial solar PV?

Typically 5 to 8 years simple payback at current UK electricity prices. The exact payback depends on the proportion of generation self-consumed (higher value than export), site orientation, and installed cost per kWp.

How much does commercial solar PV cost?

Approximately £600 to £900 per kWp installed in 2024, with larger installations achieving the lower end of the range. A 100 kWp system therefore costs around £60,000 to £90,000.

Should I add battery storage to my solar PV?

Often worthwhile, particularly for sites with significant evening consumption or interest in grid services revenue. Storage increases self-consumption proportion and can provide additional grid services income.

Do I need planning permission for commercial solar?

Permitted development typically covers rooftop installations. Ground-mounted systems above 50 kWp generally require planning permission, with specific consideration of visual impact and land use.

What is the SEG rate for commercial solar?

Installations up to 5MW can receive a supplier-set export rate. In 2024/25 the rates offered ranged widely, with untied tariffs averaging around 4.5p/kWh. Some larger sites use an on-site power purchase agreement, where a funder owns the system and sells the power to the business.

Does a commercial solar PV system need MCS certification?

Installations up to 50kW need MCS or equivalent certification to qualify for the Smart Export Guarantee. Larger commercial installations typically follow utility-scale design and installation standards rather than MCS.

Clearsight Energy
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.